ANOTHER BUSY YEAR AT ANDERSON PUMP HOUSE LTD.

Read article as printed in The Battlefords Regional Optimist.

NEW PRODUCT FLYER

Click here to see our new product lineup.

 

 

 

 

 

 

 

 

 

 

We are very excited to announce that Anderson Pump House Ltd. is now a Grundfos pump distributor.  Grundfos, leaders in stainless steel and variable speed pump technology, offer a wide range of product for many different pumping applications.  This addition to our existing pump lines gives Anderson Pump House Ltd. a very broad selection of pump products.

 

Grundfos builds stainless steel jet pumps, including the constant flow compact MQ jet pump, the 3 SQE constant pressure stainless steel submersible pump, 4, 6, 8 and 10 stainless steel submersible pumps.

 

Grundfos offers the largest selection of vertical multistage booster pumps in the world.  The CR vertical booster pump is available in many configurations including multiple pump packages controlled with VFD’s.

 

Grundfos offers a line of stainless steel sump pumps, effluent pumps and sewage pumps from ¼ to 1 ½ HP.

 

Grundfos is a world leader in hot and cold water circulator pumps.  We are very happy to have the line of Grundfos circulator pumps added to our existing products including black iron pipe and fittings, valves, manifolds, pex piping, pex piping with oxyguard and kitec piping.

 

Grundfos also has a range of solar and wind pumping packages utilizing their stainless steel pump technology with lifts of up to 350 feet.

 

Please call our office in North Battleford or Prince Albert for more information on the Grundfos pump line!

 

DECEMBER 2006

Over the past few years Anderson Pump House Ltd. has added some plumbing and hydronic heating products to our lines.

Some of these products include:

 

1       Black, brass, copper pipe and fittings

2       Complete range of valves

3       Watts pressure regulators and other accessories

4       Expansion tanks, both potable and non-potable

5       Kitec pipe and fittings

6       PVC Sch40/80 pipe and fittings

7       Pex pipe, pex pipe with oxyguard

8       Pex fittings and valves

9       Manifolds, gauges and other accessories

10 Boiler fill pump/reservoir package (An Anderson Pump House exclusive)

 

AND NOW

 

 

GRUNDFOS

 

CIRCULATING PUMPS!

 

1       Series UP small circulators

2       Comfort hot water recirculation systems

3        Versa flow UPS large wet-rotor circulators

4        Versa flow TP circulators

5        Series L circulators

WELL ABANDONMENT AND DECOMMISSIONING

DECOMMISSIONING AND PLUGGING OF ABANDONED WELLS

 We have reviewed several well abandonment procedures and recommendations from various provincial and federal government agencies.  Wells fall into one of two categories, small diameter drilled wells and large diameter bored wells.  The procedures are different for these two types of wells.  Our proposed protocol and specifications are as follows.  Please check with authorities in your area before abandoning any water well as there may be different requirements.

A.) Drilled Wells

1.) Remove any piping and pumping equipment from the well.

2.) Measure and record the water level, the total well depth, the casing diameter, and the casing type.

3.) Chlorinate the well to a level of at least 200 ppm.

4.) i.) Using Bentonite Chips: Recommended for very shallow wells only!
• Fill the entire well with EconoPlug coarse bentonite chips.  EconoPlug is a sealing material that is approved for sealing wells and bore holes.
• Be sure to follow instructions when using the bentonite chips.  Calculate the well volume and determine the volume of chips that will be required to plug the well.  All of this material must flow into the well.  Add the bentonite very slowly to prevent bridging making sure all of the bentonite goes down the well.

ii.) Using Bentonite Grout:
• While it is possible to use bentonite chips for sealing shallow drilled wells, there is a possibility of bridging occurring resulting in voids or open spaces in the water well casing.  The smaller the diameter of the well or the deeper the well, the more likely the chance for bentonite chips to bridge.  The standard recommended procedure is to use a bentonite grout/cement mixture that is pumped into the well.  The well should be filled with this grout mixture from the bottom up through a tremie pipe displacing any water from the well.  This method of well decommissioning requires specialized equipment and therefore an experienced contractor should be contacted.


5.) Excavate around the well and cut off the casing at 2.0 to 3.0 meters below ground level.  Fill, compact and mound the excavation with native clay material.

6.) Record the location to the closest building or landmark, and record a GPS location.


B.) Bored Wells

1.) Remove any piping and pumping equipment from the well.

2.) Measure and record the water level, the total well depth, the casing diameter, the casing type.

3.) Chlorinate the well to a level of at least 200 ppm.

4.) Add enough coarse bentonite chips to place a 0.3 meter plug in the bottom of the well.

5.) Fill the well with a clean locally available sandy material free of organics to a level 3.0 meters from ground surface.  Add a second 0.3 meter bentonite plug.

6.) Excavate around the well and cut off the casing at 2.0 to 3.0 meters below ground level.  Fill the balance of the well with clay and tamp.  Compact and mound the excavation with native clay material.

7.) Record the location to the closest building or landmark, and record a GPS location.

8.) Deep bored wells may require additional bentonite plugs depending upon the subsurface geology at their location.

Summary

There may be special situations where different procedures are required.  It is important to take the well decommissioning process seriously as we are protecting our most precious resource on this planet – water.

PIPE FREEZE PROTECTION

 

SERGE BARIL HEATING CABLE

November/2006

Anderson Pump House Ltd. is a stocking distributor for

Serge Baril Heat Tracing Cable. 

 

We stock two main products: 

-                A self regulating 6 watts per foot heat tracing cable that is approved for the installation on the exterior of water lines.

-                A self regulating heat tracing cable that is CSA approved for the installation inside a water line.  The only self regulating cable on the market that is approved for this application.

 

 

The IN-PIPE product gives us the ability to supply heating cable for inside water lines of any length from 0 – 252 feet on the spot!  

 

In order to maintain CSA approval the IN-PIPE product must be sold with the GTKB installation kit.  This kit includes the end seal, a quality ¾" brass compression adapter, a splicing kit, 6ft of power cord and a high quality 10 milliamp GFI plug.  We will not sell the heating cable without the kit!

 

 

 

 

Announcing: The Next Generation in Onsite Chambers for Sewage Disposal

 "Quick 4" Equalizer 36 Chamber

We are pleased to offer this new product from Infiltrator Systems Inc.  This new chamber is 4 feet long allowing more flexibility in the installation.  The chambers easily follow contours or "S" curves with their countour swivel connection. They are lightweight making them easy to handle.We now have these in stock at both our locations. Visit Infiltrator Systems Inc. for more information on this new product.

 

WOULD YOU LIKE CONSTANT PRESSURE FROM YOUR WATER SYSTEM?

With a CP Water Controller you don't have to schedule your day around your water usage.  You can do what you want, whenever you want.

Franklin Electric Constant Pressure Controllers, the Monodrive, SubDrive75 and SubDrive150, continuously monitor water demand and adjust the speed of your submersible pump to provide the water you need without pressure fluctuations.  So next time you're in the shower, your water pressure will not longer slow to a trickle when someone turns on another faucet.

Call us today for a quote on updating your water system with a CP Water Controller from Franklin Electric.

We carry a wide variety of parts to maintain your livestock waterers and yard hydrants

We carry parts for Ritchie, Edwards and Hurst livestock waterers.  We also have parts for yard hydrants.

 

If you are thinking of adding or replacing a livestock waterer, check out the quality of Ritchie.  Clean, free flowing water is critical to any cattle operation's production and profit.  Ritchie offers twenty models of cattle fountains designed to water your livestock in all weather conditions.

Thank you for visiting our News/Specials Page, please visit again – more information is coming soon.

[Home]-[About Us]-[Products]-[Brochures]-[Services]
[Contact Us]-[News/Specials]

© Copyright Anderson Pump House - Saskatchewan, Canada.